Home Page Product listing by category Reference materials, engineering tables, downloads, archives, terms and conditions Product Applications Introduction to application-specific modules A collection of technical tips about our products, troubleshooting and general RDL knowledge Contact Radio Design Labs Employment opportunities Dealer Login Radio Design Labs Banner banner.php




Stay Connected RDL on Facebook RDL on Twitter RDL on YouTube RDL RSS Feed


PRODUCT CATEGORIES > REMOTE PANELS & CONTROLS > REMOTE CONTROL - ULTRASTYLE >
EZ Products Banner

Rotary Level Control - Rotary Encoder - 0 to 10 Vdc output

RLC-10R Rotary Level Control - Rotary Encoder - 0 to 10 Vdc output

Radio Design Labs - Rotary Level Control - Rotary Encoder - 0 to 10 Vdc output



  • Rotary Encoder Remote Level Control
  • Provides 0 to 10 Vdc and Up/Down Pulse Outputs
  • 0 to 10 Vdc LED Display of Internal or External Ramp
  • Optical Encoding for Long Life
  • Noise‑Free Performance
  • RDL ULTRASTYLE Design

The RLC‑10R is the ideal choice for 0 to 10 Vdc or pulsed control from a remote location. Circuitry is based on optical encoder technology to produce long‑term, trouble‑free operation. Control is incremented up or down when the large front‑panel knob is rotated. Acceleration is provided so the rate of change is faster when the knob is rotated more rapidly, yielding a responsive feel. The LED ring display encircling the control knob operates as a virtual pointer. The input to this display is a 0 to 10 Vdc signal, either internal or external.

A 0 to 10 Vdc output provides single point control for RDL VCA products and other industry 0 to 10 Vdc controlled equipment. If multiple control points are desired, individual up or down pulse outputs may be connected to RDL RU‑VCA products and various industry products. A rear‑panel jumper sets the pulse outputs to either produce +15 Vdc pulses (RDL RU‑VCA) or momentary open‑collector pulses.

In the event of power loss, internal non‑volatile memory stores the last level value. When power returns, the 0 to 10 V output will return to the operating level present when power was lost.

Typical Performance:

Ramp Output:

0 to 10 Vdc

Pulse Outputs (2):

PULSE UP, PULSE DOWN (open‑collector or +15 V pulse)

Pulse Output Current:

20 mA (open collector)

Display RAMP IN Input Resistance:

200 kΩ

Display Input Voltage:

0 to 10 Vdc

Rotations (approximate min‑to‑max):

5 (slow rotation, no acceleration)
3 (medium rotation, with acceleration)
1 (fast rotation counterclockwise, anti‑feedback mode)

Power Requirement:

GROUND‑REFERENCED, 24 to 33 Vdc @ 50 mA

Backbox Mounting Req.:

Height: 2.73 in.   6.93 cm

Width: 1.80 in.   4.57 cm

Depth: 1.50 in.   3.81 cm

Ambient Operating Environment:

0° C to 55° C


Rotary Encoder Remote Level Control, Provides 0 to 10 Vdc Up/Down Pulse Outputs, 0 to 10 Vdc LED Display of Internal External Ramp, Optical Encoding for Long Life, Noise-Free Performance, RDL ULTRASTYLE Design, The RLC-10R ideal choice 0 to 10 Vdc pulsed control from remote location Circuitry based optical encoder technology to produce long-term, trouble-free operation Control incremented up down when large front-panel knob rotated Acceleration provided so rate of change faster when knob rotated more rapidly, yielding responsive feel LED ring display encircling control knob operates virtual pointer input to this display 0 to 10 Vdc signal, either internal external, A 0 to 10 Vdc output provides single point control RDL VCA products other industry 0 to 10 Vdc controlled equipment If multiple control points desired, individual up down pulse outputs connected to RDL RU-VCA products various industry products rear-panel jumper sets pulse outputs to either produce +15 Vdc pulses (RDL RU-VCA) momentary open-collector pulses, In event of power loss, internal non-volatile memory stores last level value When power returns, 0 to 10 V output will return to operating level present when power was lost, format converter Data/Installation


Mounting Accessories:

Wall Box Adapter - Single Unit to Double BoxUS-A1
Wall Box Adapter - Single Unit to Double Box

Universal Wall Box - Single - Mounts RDL remote controls & wall platesWB-1U
Universal Wall Box - Single - Mounts RDL remote controls & wall plates


Related Products:

RU-VCA2D
Local/Remote Control Audio Attenuator - Stereo

ST-VCA2
Voltage Controlled Amplifier - 0 to 10 Vdc

RLC10K
Remote Level Control - 0 to 10 kΩ

RU-VCA2
Local/Remote Control Audio Attenuator - Mono

RLC10KM
Remote Level Control with Muting

ST-VCA3
Voltage Controlled Amplifier


Home
Products
Reference
Applications
Introduction
Tech Tips
Contact us
Employment
Login
Sitemap

Copyright © 2010 Radio Design Labs, Inc. RDL, Radio Design Labs, the RDL logo, STICK-ON, RACK-UP and the Rack-Up logo are registered trademarks of Radio Design Labs, Inc. Flat-Pak, RCX, SourceFlex, SupplyFlex, Sure-Lok, TX, ULTRASTYLE, and Specialists in Practical Precision Engineering are trademarks of Radio Design Labs, Inc. All other trademarks are the property of their respective owners. Typical Performance reflects product at publication time exclusive of EMC data, if any, supplied with product. Date last modified: June 29 2010

...